Double
cylinder twin piston pump, positive displacement, air motor powered,
high pressure, with drop tube intake tubes mounted on adjustably
calibrated steel post stand with can top retainer attached to two-wheeled
twin-can transport dolly.
Cylinders
and ratios - 2 cylinders at 1:1 ratio
Fluid Output – gallons per hour - 21 gal/hr
Fluid Output – gallons per minute - 0.36 gpm
Pump cycles per minute - 60
Pump gallons per cycle - 0.002942
Maximum fluid output pressure - 2000 psi
Wetted parts description - zinc-plated carbon steel, stainless steel,
carbon steel, polyurethane, polyethylene, Teflon, Delrin, chrome
plating, leather, rubber, V-Max UHMWPE, aluminum, tungsten carbide;
* Delrin and Teflon are registered trademarks of DuPont Co.
Height
- 36 inches
Length - 12 inches
Width - 12 inches
Weight - 60 lbs Crate size: 24” x 24” x 40”
Air
volume requirement - 20 cpm (will vary per operating pressures and
durations)
Inlet max air pressure - 150 psi
DOCUMENTS
Air
Motor Schematic Diagram
Air Motor Parts List
Air Motor Manual
Displacement Pump
Repair Manual
Displacement Pump Schematic
Diagram
Falcon Pump Operations Manual
NOTICE:
All written and visual data contained in this document reflect the
latest product information available at the time of publication.
Publisher reserves the right to make changes at any time without
notice.
Click
on images for larger view.
(Picture actually shows the Falcon 46 for illustration only)
Return
to Grout Pumps
STATEMENT
Strata Tech believes that the information herein is an accurate
description of the general properties and characteristics of the
product(s), but the user is responsible for obtaining current information
because the body of knowledge on these subjects is constantly enlarged.
Information herein is subject to change without notice. Field conditions
also vary widely, so users must undertake sufficient verification
and testing of the product or process herein to determine performance,
safety, usefulness, and suitability for their own particular use.
Strata Tech warrants only that the product will meet Strata Techs
then-current specification. NO WARRANTY OF SUITABILITY OR FITNESS
FOR A PARTICULAR PURPOSE IS MADE. Users should not assume that all
safety requirements for their particular application(s) have been
indicated herein and that other or additional actions and precautions
are not necessary. Users are responsible for always reading and
understanding the Material Safety Data Sheet, the product technical
literature, and the product label before using any product or process
mentioned herein and for following the instructions contained therein.
Copyright C 1990 by Strata Tech, Inc. All rights reserved. No part
of this publication may be reproduced or disseminated in any form,
by any means, or stored in any electronic format without prior written
permission from Strata Tech except as allowed under the U.S. Copyright
Act, 1976. Printed in USA. REV 980421.
Will Jaques
Return
to Top
|